    Here is the solution to TM100 transponder key programmer software error after opened module authorization.

     

    Customer problem:

    I ordered TM100 with basic module half an year ago. I recently paid you factory to open authorization for Toyota Peugeot Ford Citroen and Mercedes Benz modules, but I did not see the new modules added and TM100 gave me following error message:

    tm100-interface-reflash

    “Connection warning: TM100 interface need reflash (Part 1.)

    Please wait while the TM100 is programmed.

    Do not disconnect TM100 from the computer.”

    tm100-interface-reflash-2

    “File was downloaded successfully.

    Please save your works.

    Click YES to update, NO to exit.”

    tm100-installed-module

    tm100-payable-module

    “Payable module (ID:10). Please contact with your dealer for more detail information.”

    tm100-unable-to-execute-file

    “Unable to execute file:

    E:/Program Files/TM100 Key Programmer Software/USB Interface Drivers/CDM20814

    CreateProcess failed; code 3.

    Le chemin d’acces specifie est introuvable.”

     

    Solution from obdii365.com engineer:

    If you open the authorization, please uninstall previous TM100 software and delete all files. Re-install the TM100 programmer software again. It will work.