Skip to content
Key Programmer

    TM100 need reflash after open authorization(solved)

    (0)

    Here is the solution to TM100 transponder key programmer software error after opened module authorization.

     

    Customer problem:

    I ordered TM100 with basic module half an year ago. I recently paid you factory to open authorization for Toyota Peugeot Ford Citroen and Mercedes Benz modules, but I did not see the new modules added and TM100 gave me following error message:

    tm100-interface-reflash

    “Connection warning: TM100 interface need reflash (Part 1.)

    Please wait while the TM100 is programmed.

    Do not disconnect TM100 from the computer.”

    tm100 interface reflash-1

    “File was downloaded successfully.

    Please save your works.

    Click YES to update, NO to exit.”

    tm100 interface reflash 2-2

    tm100 installed module-3

    “Payable module (ID:10). Please contact with your dealer for more detail information.”

    tm100 payable module-4

    “Unable to execute file:

    E:/Program Files/TM100 Key Programmer Software/USB Interface Drivers/CDM20814

    CreateProcess failed; code 3.

    Le chemin d’acces specifie est introuvable.”

     

    Solution from obd365.com engineer:

    If you open the authorization, please uninstall previous TM100 software and delete all files. Re-install the TM100 programmer software again. It will work.

    V3.09 TM100 Transponder Key Programmer with Full Software (62 Module)

    Rate this article (0)